FUNCTIONS
DOSING
Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph – load indicator. For industrial scales it is possible to use a control systems of dosing process.
LABELLING
Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
LABELLING
Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
PARTS COUNTING
Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
FORMULATION
Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
STATISTICS
Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
CHECKWEIGHING
Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
DATASHEET
| Maximum quantity of verification units | 6000 e |
| OIML Class | III |
| Display | 15.6” graphic colour touchscreen |
| Protection class | IP 68 |
| USB Interface | 4×USB 2.0 (2×USB-A, 2×M12 4P) |
| Ethernet | 2×10/100/1000 Mbit (2×RJ45 hermetic) |
| Profibus DP Interface | operation mode: slave |
| Serial Interface | 2×RS232, RS485 (2×M12 8P) |
| Inputs/Outputs (option) | 4IN / 4OUT (2×ports M12 8P or 2×cables fed through the cable gland) |
| Additional weighing platform module | additional max. 3 pcs (metrological parameters as in the main weighing platform) |
| External buttons PRINT, TARA, START (option) | terminal with 4IN/4OUT (M12 8P connector) is required |
| Power consumption max. | 50 W |
| Maximum quantity of divisions from converter | 838 860 ×10 |
| Maximum increase of signal | 19.5 mV |
| Minimum volatge per verification unit | 0.4 µV |
| Maximum voltage per verification unit | 3.25 µV |
| Minimum load cell impedance | 80 Ω |
| Maximum load cell impedance | 1200 Ω |
| Load cell excitation voltage | 5V DC |
| Connection of load cells | 4 or 6 wires + shield |
| Operating temperature | 0 ÷ +40°C |
| Relative humidity | 10% ÷ 85% RH no condensation |
| Touch panel | infrared |
| Housing | stainless steel |
| Operating system | Microsoft Windows 10 IoT |
| Processor | Intel® Pentium® N3710 on-board SoC (2.56GHz, quad-core, 2MB cache) |
| Chipset | Intel® HD Graphics Gen 7 |
| Memory | 4GB 1066/1333 MHz DDR3L max 8 GB |
| Data memory | SSD 128 GB |
| Packaging dimensions | 560×360×240 mm |
| Net weight | 10.5 kg |
| Gross weight | 11.5 kg |
COMPATIBLE WITH
- F1 Mass Standard-knob weights without adjusment chamber, set
- Stainless steel HRP. H Platforms
- HRP Platforms High Capacity
- Waterproof stainless steel platforms
- Mild steel powder coated weighing platforms
- Platforms in plastic casing
- Waterproof stainless steel platforms
- Stainless steel ramp platforms with LD lifting system
- Ramp stainless steel platforms
- Stainless steel platforms, pit version
- Mild steel powder coated weighing platforms
- E2R System
- R-LAB
- RAD-KEY
- labVIEW Driver
- Receipt Printer
- Label Printers
- Moxa Uport 1110 Converter
- RS 232 cables (scale – ZEBRA printer)
- USB Adapter
- USB cables (terminal – terminal)
- IN/OUT Cables
- RS 232 cables (scale- EPSON printer)
- USB cables (scale – Ethernet)
- USB cable (scale – printer)
- RS 232, RS 485 cables
- Keypad, external switches
- Barcode Scanners
- Displays